    This simulation
        explores the problem of measuring the height of a small peak
        (also called a "child peak") that is buried in the tail of a
      much stronger overlapping peak (a "parent peak"),
        in the especially challenging case that the smaller peak is not even visible to
        the unaided eye. Three different measurement tools will be
        explored: iterative
          least-squares, classical least-squares regression,
        and peak detection, using the
        Matlab/Octave tools peakfit.m,
        cls.m, or findpeaksG.m,
        respectively. (Alternatively, you could use the corresponding spreadsheet
          templates). 
        
        In this example the larger peak is located at x=4 and has a
        height of 1.0 and a width of 1.66; the smaller measured peak is
        located at x=5 and has a height of 0.1 and also with a width of
        1.66. Of course, for the purposes of this simulation, we pretend
        that we don't necessarily know all of these facts and we will
        try to find methods that will extract such information as
        possible from the data, even if the signal is noisy. The
        measured peak is small enough and close enough to the stronger
        overlapping peak (separated by less than the width of the peaks)
        that it never forms a maximum
      in the total signal. So  it looks like there is only
      one peak, as
        shown on the figure on the right. For that reason the
        findpeaks.m function (which automatically finds peak maxima)
        will not be useful by itself to locate the smaller peak. Simpler
        methods for detecting the second peak also fail to provide a way
        to measure the smaller second peak, such as inspecting the
        derivatives of the signal (the smoothed fourth derivative shows
        some
          evidence of asymmetry, but that could just be due to the
        shape of the larger peak), or Fourier self-deconvolution to
        narrow the peaks so they are distinguishable, but that is
        unlikely to be successful with this much noise. Least-squares
        methods work better when the signal-to-noise ratio is poor, and they can be fine-tuned to make use of available
        information or constraints, as will be demonstrated below.
it looks like there is only
      one peak, as
        shown on the figure on the right. For that reason the
        findpeaks.m function (which automatically finds peak maxima)
        will not be useful by itself to locate the smaller peak. Simpler
        methods for detecting the second peak also fail to provide a way
        to measure the smaller second peak, such as inspecting the
        derivatives of the signal (the smoothed fourth derivative shows
        some
          evidence of asymmetry, but that could just be due to the
        shape of the larger peak), or Fourier self-deconvolution to
        narrow the peaks so they are distinguishable, but that is
        unlikely to be successful with this much noise. Least-squares
        methods work better when the signal-to-noise ratio is poor, and they can be fine-tuned to make use of available
        information or constraints, as will be demonstrated below.
       
        The selection of the best method will depend on what is known
        about the signal and the constraints that can be imposed; this
        will depend in your knowledge of your experimental signal. In
        this simulation (performed by the Matlab/Octave script SmallPeak.m),
        the signal is composed of two Gaussian peaks (although that can
        be changed if desired in line 26). The first question is: are
        there more than one peak there? If we perform an unconstrained
        iterative fit of a single Gaussian to the data, as shown in the figure on the
        right, it shows little or no evidence of a second peak - the
        residuals look pretty random. (If you could reduce the noise, or
        ensemble-average even as few as 10
        repeat signals, then the noise would be low enough to see
        graphical evidence of a second peak). But as
        it is, there is nothing that suggests a second peak.
        
        But suppose we suspect that there should
        be another peak of the same Gaussian
        shape just on the right side of the  larger peak. We can try
        fitting a pair of Gaussians to the data (figure on the left), but in
        this case the random noise is enough that the fit is not stable.
        When you run SmallPeak.m,
        the script performs 20 repeat fits (NumSignals in line 20) with
        the same underlying peaks but with 20 different random noise
        samples, revealing the stability (or instability) of each
        measurement method. The fitted peaks in Figure window 1 bounce
        around all over the place as the script runs, as you can see in
        the animation on the left. The fitting error is on average lower that the
        single-Gaussian fit, but that by itself does not mean that the
        peak parameters so measured will be reliable; it could just be
        "fitting the noise". If it were
          isolated all by itself, the small
        peak would have a S/N ratio of about 5 and it could
        be measured to a peak height precision of about 3%, but the
        presence of the larger interfering peak makes the measurement
        much more difficult. (Hint: After running SmallPeak.m the first
        time, spread out all the figure windows so they can all be seen
        separately and don't overlap. That way you can compared the
        stability of the different methods more easily.)
larger peak. We can try
        fitting a pair of Gaussians to the data (figure on the left), but in
        this case the random noise is enough that the fit is not stable.
        When you run SmallPeak.m,
        the script performs 20 repeat fits (NumSignals in line 20) with
        the same underlying peaks but with 20 different random noise
        samples, revealing the stability (or instability) of each
        measurement method. The fitted peaks in Figure window 1 bounce
        around all over the place as the script runs, as you can see in
        the animation on the left. The fitting error is on average lower that the
        single-Gaussian fit, but that by itself does not mean that the
        peak parameters so measured will be reliable; it could just be
        "fitting the noise". If it were
          isolated all by itself, the small
        peak would have a S/N ratio of about 5 and it could
        be measured to a peak height precision of about 3%, but the
        presence of the larger interfering peak makes the measurement
        much more difficult. (Hint: After running SmallPeak.m the first
        time, spread out all the figure windows so they can all be seen
        separately and don't overlap. That way you can compared the
        stability of the different methods more easily.)

        But suppose that we have reason to expect that the two peaks will have the same width, but we don't know what that width might be. We could
        try an equal width Gaussian fit (peak shape #6, shown in Matlab/Octave
        Figure window 2); the resulting fit is much more stable and
        shows that a small peak is located at about x=5 on the right of
        the bigger peak, shown below on the left.  On the other
        hand, if we know the peak positions beforehand, but not the widths, we can use a fixed-position Gaussian
        fit (shape #16) shown on the right  (Figure window 3). In
        the very common situation where the objective is to measure an unknown
        concentration of a known component,
        then it's possible to prepare standard samples where the
        concentration of the sought component is high enough for its
        position or width to be determined with certainty. 
    
So far all of these examples have used iterative
        peak fitting with at least one peak parameter (position and/or
        width) unknown and  determined
        by measurement. If, on the other hand, all
        the peak parameters are known except the peak height,
        then the faster and more direct classical least-squares regression
        (CLS) can be employed (Figure window 4). In this case you need
        to know the peak position and width of both the measured and the
        larger interfering peaks (the computer will calculate their
        heights). If the positions and the heights really are constant
        and known, then this method gives the best stability and 
        precision of measurement. It's also computationally faster,
        which might be important if you have lots of data to process
        automatically.
determined
        by measurement. If, on the other hand, all
        the peak parameters are known except the peak height,
        then the faster and more direct classical least-squares regression
        (CLS) can be employed (Figure window 4). In this case you need
        to know the peak position and width of both the measured and the
        larger interfering peaks (the computer will calculate their
        heights). If the positions and the heights really are constant
        and known, then this method gives the best stability and 
        precision of measurement. It's also computationally faster,
        which might be important if you have lots of data to process
        automatically.  
        
        The problem with CLS is that it fails to give accurate
        measurements if the peak position and/or width changes without
        warning, whereas two of the iterative methods (unconstrained
        Gaussian and equal-width Gaussian fits) can adapt to such
        changes. It some experiments it quite common to have small
        unexpected shifts in the peak position, especially in
        chromatography or other flow-based measurements, caused by
        unexpected changes in temperature, pressure, flow rate or other
        instrumental factors. In SmallPeaks.m, such x-axis shifts can be
        simulated using the variable "xshift" in line 18. It's initially
        zero, but if you set it to something greater (e.g. 0.2) you'll
        find that the equal-width Gaussian fit (Figure window 2) works
        better because it can keep up with the changes in x-axis shifts.
But with a greater x-axis shift (xshift=1.0) even the equal-width fit has trouble. Still, if we know the separation between the two peaks, it's possible to use the findpeaksG function to search for and locate the larger peak and to calculate the position of the smaller one. Then the CLS method, with the peak positions so determined for each separate signal, shown in Figure window 5 and labeled "findpeaksP" in the table below, works better. Alternatively, another way to use the findpeaks results is a variation of the equal-width iterative fitting method in which the first guess peak positions (line 82) are derived from the findpeaks results, shown in Figure window 6 and labeled "findpeaksP2" in the table below; that method does not depend on accurate knowledge of the peak widths, only their equality.
Each time you run
        SmallPeaks.m, all of these methods are
          computed "NumSignals" times (set in
        line 20) and compared in a table giving the average peak height
        accuracy of all the repeat runs: 
        
      xshift=0
          Unconstr. EqualW  FixedP FixedP&W findpeaksP
          findpeaksP2
          35.607    16.849  5.1375 
          4.4437   13.384     16.849
          
        xshift=1
          Unconstr. EqualW  FixedP FixedP&W findpeaksP
          findpeaksP2
          31.263    44.107  22.794 
          46.18    10.607     10.808
      
      Bottom line. The more
        you know about your signals, the better you can measure them. A
        stable signal with known peak positions and widths is the most precisely
        measurable in the presence of random noise ("FixedP&W"), but
        if the positions or widths vary from measurement to measurement,
        different methods must be used, and precision is degraded
        because more of the available information is used to account for
        changes other than the ones you want to measure.
      
This page is part of "A Pragmatic Introduction to Signal
          Processing", created and maintained by Prof. Tom O'Haver ,
      Department of Chemistry and Biochemistry, The University of
      Maryland at College Park. Comments, suggestions and questions
      should be directed to Prof. O'Haver at toh@umd.edu. Updated July, 2022.